2009 International Fuel Gas Code: Looseleaf Version by International Code Council

By International Code Council

The 2009 foreign gas fuel Code units forth specifications that deal with the layout and set up of gas fuel platforms and gas-fired home equipment, in line with the most up-tp-date details and expertise to be had. the necessities are performance-driven, making this an efficient instrument and worthwhile addition to any Code library.

Show description

Read or Download 2009 International Fuel Gas Code: Looseleaf Version PDF

Similar design & construction books

Audel Carpenters And Builders Layout Foundation And Framing

This is wisdom you could construct on even if you are development a garage shed or your dream apartment, an analogous ideas govern picking a domain, surroundings the root, erecting the partitions, and placing at the roof. this convenient how-to advisor has been completely revised and up to date to hide new development fabrics and the newest thoughts in development and framing.

Knowledge Management in the Construction Industry: A Socio-Technical Perspective

Wisdom administration within the development undefined: A Socio-Technical point of view offers techniques, functions and case experiences on how the development is trying to appreciate after which combine recommendations of data administration or innovation into their paintings and techniques. . This reader has obvious many definitions.

Management, Quality and Economics in Building

This publication provides the complaints of a global symposium which aimed to set up on the maximum point the simplest perform and study in 3 very important medical and technical subject matters in the area of residentaionl builsings around the eu neighborhood: caliber administration and legal responsibility development economics development administration.

Statistics for Mining Engineering

Many components of mining engineering assemble and use statistical info, supplied by means of watching the particular operation of apparatus, their structures, the improvement of mining works, floor subsidence that accompanies underground mining, displacement of rocks surrounding floor pits and underground drives and longwalls, among others.

Additional info for 2009 International Fuel Gas Code: Looseleaf Version

Example text

5 Indoor locations. Furnaces and boilers installed in closets and alcoves shall be listed for such installation. 6 Outdoor locations. Appliances installed in outdoor locations shall be either listed for outdoor installation or provided with protection from outdoor environmental factors that influence the operability, durability and safety of the appliances. 7 Pit locations. Appliances installed in pits or excavations shall not come in direct contact with the surrounding soil. The sides of the pit or excavation shall be held back a minimum of 12 inches (305 mm) from the appliance.

1 Sloped roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of 3 units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a level platform shall be provided on each side of the appliance or equipment to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards.

The clearance to these appliances shall not interfere with combustion air; draft hood clearance and relief; and accessibility for servicing. 1 Appliances installed in rooms that are large in comparison with the size of the appliance. Central-heating furnaces and low-pressure boilers installed in rooms large in comparison with the size of the appliance shall be installed with clearances in accordance with the manufacturer's instructions. 2 Appliances installed in rooms that are not large in comparison with the size of the appliance.